AndonTapBY ALTITUDE AP
Specifications · preliminary · HW V6 · FW 1.5

Specifications

Values come from the V6 circuit design and from firmware 1.5 tests in emulation. They are not yet measured on V6 hardware and may change after first-article testing. Items marked Planned or "to be confirmed" are not available or not yet verified.

Power

DC supply24 VDC nominal, 3-pin plug +24V / 0V / PEWorking range to be confirmed in qualification.
ProtectionReverse-polarity diode, 0.5 A resettable fuse, TVS clamp
Protective earthPE on the power plug · RJ45 shield to PE through 1 nF / 1 MΩ
Power over EthernetIEEE 802.3af, Class 0, mode A or BBuilt into every unit. 1500 V isolated PD module.
USB-C5 V, for bench setup
24V OUT24 V from an on-board boost, 0.1 A resettable fuseOn the IN5-8 plug, for dry contacts. Works on PoE alone. Full-load capability to be confirmed.
ConsumptionTo be measured on V6 hardware

Inputs 1-4 · universal

Channels4, one shared COM-AOne voltage per group: a 120 V lamp and a 24 V switch cannot share COM-A.
Input voltage24 VDC or 120 VAC 50/60 Hz, automaticEither polarity on DC.
Input currentAbout 2 mA, constant current (1.3-2.8 mA)Design values.
On thresholdAbove 9.3 V worst case (design value)
IsolationBarrier between the field side and logic, crossed only by the optocouplersDesigned as reinforced insulation for 120 VAC (reinforced-rated optocouplers, 6 mm creepage target). Not yet lab-evaluated.
SurgeBidirectional TVS per channel
Sampling1 kHz · debounce, flash window and count debounce set per unit
RolesStack-light lamp, part counter, signal, unused

Inputs 5-8 · 24 VDC

Channels4, one shared COM-B
Input voltage24 VDC onlyNever connect 120 VAC to this plug.
WiringSinking or sourcing, bidirectional optocouplerCOM-B to 0V: sourcing (PNP, or dry contacts fed from 24V OUT). COM-B to +24V: sinking (NPN).
On thresholdAbout 8 V (design value)12 V machine signals switch with margin.
Input currentAbout 4.8 mA at 24 V (design value)
ProtectionTVS clamp per input · RC filter on the logic side
UsesDoor switch, feed hold, part count, lube / air / coolant switches, M-code relays, operator call
FirmwarePlanned PlannedFirmware 1.5 does not read inputs 5-8 on V6 hardware yet.

Current inputs

Channels2 (CT1 spindle, CT2 auxiliary)
CT typeVoltage-output split-core, 333 mV or 1 V AC full scale
CT rating1-5000 A, set in setup · 1-20 wire passes
MeasurementTrue RMS, 16-bit ADC, 0.01 A resolution
Spindle levelsStopped · turning · cutting, 10 % hysteresisThresholds suggested from motor FLA or captured live.

Network and setup

Ethernet10/100BASE-TX, RJ45 with link and activity LEDs
AddressingStatic IP (default) or DHCP · no traffic until set · IPv6 off
Modbus TCPServer, port 502, any unit ID, 4 clients
EtherNet/IPAdapter, explicit and class 1 I/O · EDS file suppliedConformance not yet tested; vendor ID is a placeholder until ODVA assigns one.
Remote writesOff, basic (default) or fullSets what Modbus and EtherNet/IP clients may change.
SetupUSB-C console and Bluetooth LE, same commandsWeb setup app in Chrome or Edge; Bluetooth from a phone. Over the plant network: open http://<unit IP> in a browser and the unit serves the same app, PIN-protectedPlanned
SecurityOptional setup PIN · Bluetooth on only after a CFG press, or when no IP is set

Radio

LoRaWANOptional RAK3172 module Plannedu.FL pigtail to a bulkhead SMA jack in the top end wall. Firmware support and frequency-plan variants to be confirmed. The radio stays off until LoRaWAN is enabled in setup and an antenna is confirmed.
AntennaSold separatelyMetal cabinet: roof-mounted antenna, coax down to the SMA jack. A whip on the jack only in plastic cabinets or open mounting. See accessories.
Wi-FiNot used (off in firmware)

Processor and memory

MCUESP32-S3, dual core 240 MHz, BLE 5
CountersFRAM, written every second
ClockBattery-backed RTC, CR1220 cell
SettingsFlash with a FRAM backup copy · kept over firmware updates
Firmware updateUSB-C from a browser, or over the network with automatic rollbackNetwork updates only while an update window is open. Update images are not signed yet.

Mechanical and environment

MountingTS35 × 7.5 DIN rail (EN 60715), screwdriver release
Size (W × H × D)26.4 × 153.6 × 83.2 mmCurrent enclosure. The V6 front-face openings are being updated; final size to be confirmed.
HousingPA12 nylon, dyed black · 2 × M3 screws
CoolingPassive, vent slots in both end faces
Indicators5 LEDs through light pipes on the front bezel
Operating temperaturePending qualification
ApprovalsNone at this time · for use inside an IP20 control panel
Data the unit serves

One fixed register map

The layout is the same on every unit, so one Kepware template or one Logix UDT covers a whole floor. This is the firmware 1.5 map. V6 inputs 5-8 are planned: their data is added after the current map, so existing clients do not move.

Modbus input reg.DataType
0Status bits: inputs, spindle, 24 V, PoE, link, FAULTU16
8 · 9Machine state · spindle levelU16
10-15Input states: off, on, flashingV6: inputs 1-4 today; slots 5-6 for inputs 5-6 once their firmware is done.U16
16-19Spindle and CT2 current, 0.01 A RMSU32
20-55Per input: count (or parts), on time, flashing timeU32
56-65Spindle on time, cut time, starts · CT2 run time, startsU32
66-83Seconds in each machine state · state changesU32
84-98Boot count, powered time, clients, time in current state, CT setup, reset reason, diagnostics, remote-write levelU16 / U32
100-123Machine name and asset ID, ASCIIString
after 123Inputs 7-8: state, count, on time, flashing time PlannedU16 / U32

Holding registers 1000-1123 mirror input registers 0-123 for clients that only read FC 03. EtherNet/IP: input assembly 100 carries the same 200 bytes, output assembly 150 (4 bytes) takes commands, assembly 101 holds the name. 32-bit values are low word first and start on an even register. Machine states: 0 Unknown, 1 Off, 2 Idle, 3 Running, 4 Alarm, 5 Setup, 6 Warning, 7 Maintenance. The full table, with this machine's lamp and CT names, is on the setup app's Data map page.